Centrifugal blower that works with low rotation speed
The machine, designed by dr Radomir Magiera and prof. Władysław Kryłłowicz, was made for high-circulating research on stability and flow monitoring. The signals received from this device work as a test for detection method of stable flows, since the device has been extensively tested in various working conditions. Due to its flexible structure, the machine can work in pumping conditions.
Compressor's parameters |
Value |
Nominal mass flow |
0,8 kg/s |
Nominal rotation speed |
120 Hz |
Nominal pressure increase |
1.12 |
Diffuser |
vaneless |